Integrating luminous flux over any angular cone from EULUMDAT files with Python

Measuring the total luminous flux of a luminaire is straightforward. But for practical photometric analysis, you often need the flux emitted within a specific angular zone: the main beam of a downlight, the UGR-relevant upper hemisphere of an indirect luminaire, or any arbitrary cone that a standard characterises. eulumdat-analysis v1.3.0 adds luminous_flux_range — a function that integrates the luminous flux over any gamma window $[\gamma_{\min}, \gamma_{\max}]$ using the same CIE 190 trapezoidal method as the existing luminous_flux function, with correct handling of partial angular zones. ...

May 11, 2026 · 4 min · Vincent B.