After a goniophotometric measurement, the photometric file may not be oriented the way you need it. The C=0° direction defined in the file depends on how the luminaire was mounted on the goniometer — and this may not match the reference orientation required by a standard, a client, or your archiving convention.
eulumdat-analysis v1.4.0 adds
rotate — a function that applies an azimuthal rotation of alpha degrees to
the intensity matrix of a Ldt object and returns a new corrected Ldt,
ready to be passed to the rest of the eulumdat-* ecosystem.
For a field-by-field description of the EULUMDAT format and ISYM codes, see The EULUMDAT file format — a complete technical reference.
For an introduction to the package and the
half_anglefunction, see Computing beam half-angles from EULUMDAT files with Python.
The C-plane convention in EULUMDAT
An EULUMDAT file stores the luminous intensity distribution as a matrix of MC × NG values: MC azimuthal C-planes (0° to 360°) and NG polar γ-angles (0° to 180°). The C-plane labels in the header are fixed — they always run 0°, step°, 2·step°, … — but the physical direction they point to depends on how the luminaire was mounted during measurement.
For a luminaire with a non-symmetric distribution — a single asymmetric reflector, a linear LED strip, or a road lighting optic — the C=0° direction in the photometric file should correspond to a clearly defined physical reference: the longitudinal axis of a road, the main emission direction, or the axis specified in the applicable standard (e.g. EN 13032-1 or CIE 121).
When this alignment is off, all downstream calculations (UGR tables, luminance
diagrams, polar plots) are computed against the wrong reference. rotate
corrects this directly in the intensity matrix.
How the rotation works
A rotation by alpha degrees corresponds to a circular shift of the
C-plane profiles in the intensity matrix. The profile that was recorded at
C-plane $C_i$ is placed at C-plane $C_{i + \alpha}$:
where $n_{\text{shift}} = \operatorname{round}(\alpha / \Delta C) \bmod M_C$ and $\Delta C$ is the angular step between C-planes.
The C-plane labels in the header are not modified — they always remain 0°, $\Delta C$, $2\Delta C$, … The rotation only reorders the profiles that are assigned to those labels.
Installation
| |
Quick start
| |
Valid rotation angles
alpha must be a multiple of the angular step $\Delta C$ stored in the
file. On a standard 15°×5° grid, valid rotations are …, −30°, −15°, 0°, 15°,
30°, 45°, 60°, 75°, 90°, …
| |
The tolerance for multiple-detection is ±1 × 10⁻⁹, so small floating-point
rounding errors in alpha are accepted.
ISYM and the output file
eulumdat-py always expands the intensity matrix to the full MC × NG grid when
reading a file, regardless of the ISYM code stored in the header. rotate
therefore works on any input ISYM.
The output file always has ISYM = 0 (full matrix), even if the source had a symmetric ISYM. This is correct: after a rotation, the original symmetry is no longer guaranteed to hold relative to the new C-plane orientation.
Source object is never modified
rotate returns a new Ldt object. The original is never mutated:
| |
Practical use cases
Correcting a mounting offset. A luminaire measured with C=0° pointing west instead of north needs a 90° correction before the file is delivered to the client or archived:
| |
Normalising before further processing. The C=0° direction should be the main beam axis before computing a UGR catalogue, generating a polar diagram, or calculating a luminance table:
| |
Verifying rotational symmetry. For a nominally symmetric luminaire, the distributions at C=0° and C=90° should be identical after a 90° rotation:
| |
Return values and errors
| Case | Behaviour |
|---|---|
alpha is a multiple of $\Delta C$ | Returns a new Ldt with ISYM=0 |
alpha = 0° or alpha = 360° | Returns an identical copy |
alpha not a multiple of $\Delta C$ | Raises ValueError with the detected step and example valid values |